Stranded PVC Copper Cable 3 Core 70 mm, 0.6/1kV, 500 M | RESCAB

Stranded copper power cable (CU/PVC/PVC), 3 phase, 70mm2 size conductor, 0.6/1kV, The PVC outer jacket provides additional protection to the cable from mechanical damage caused by shock, friction, and abrasion. Produced by Red Sea Cables Company (RESCAB).

  • Conductor: Stranded Copper
  • Insulation Material: PVC (Polyvinyl Chloride)
  • Outer Sheath: PVC
  • Voltage: 0.6/1kV
  • Number of Cores: 3
  • Conductor Size (Cross-Sectional Area): 70 mm2
  • Number of wires: 19
  • Nominal Insulation Thickness: 1.4 mm
  • Nominal Sheath Thickness: 1.9 mm
  • Approx Overall Diameter: 35 mm
  • Max DC Conductor Resistance at 20°C: 0.268 ohm/km
  • Weight: 2690 kg/km
  • Standard Length: 500 meters
  • Phase Core Color: brown, black, grey
  • Standard: BS 5467
Contact Us

Stranded PVC Copper Cable 3 Core 70 mm, 0.6/1kV, 500 M | RESCAB

Unarmored stranded copper electric cable (CU/PVC/PVC), produced by Red Sea Cables (RESCAB) Company, 3 core + neutral line, 3×150 + 70sq mm size, 0.6/1kV, it suitable for indoor and outdoor applications where there is no risk of mechanical damage.

  • Conductor: Stranded Copper
  • Insulation Material: PVC (Polyvinyl Chloride)
  • Outer Sheath: PVC
  • Voltage: 0.6/1kV
  • Number of Cores: 3.5 Core (3 Core + Neutral Line)
  • Conductor Size (Cross-Sectional Area): ( 3cx150 mm2 ) + 70mm2
  • Number of Phase Wires: 37
  • Number of Neutral Wires: 19
  • Nominal Insulation Thickness of Phase: 1.8 mm
  • Nominal Insulation Thickness of Neutral: 1.4 mm
  • Nominal Sheath Thickness: 2.4 mm
  • Approx Overall Diameter: 48 mm
  • Max DC Conductor Resistance at 20°C (Ph): 0.124 ohm/km
  • Max DC Conductor Resistance at 20°C (Ne): 0.268 ohm/km
  • Weight: 6050 kg/km
  • Standard Length : 500 meters
  • Phase Core Colors: (Blue, Brown, Black, Grey)
  • Standard: BS 5467, 6346
Contact Us

Stranded PVC Copper Cable 3 Core 70 mm, 0.6/1kV, 500 M | RESCAB

Stranded copper power cable (CU/PVC/PVC), 3 phase, 70mm2 size conductor, 0.6/1kV, Excellent electrical insulation by PVC ensures the safety of people and property, produced by Red Sea Cables Company (RESCAB).

  • Conductor: Stranded Copper
  • Insulation Material: PVC (Polyvinyl Chloride)
  • Outer Sheath: PVC
  • Voltage: 0.6/1kV
  • Number of Cores: 3
  • Conductor Size (Cross-Sectional Area): 70 mm2
  • Number of wires: 19
  • Nominal Insulation Thickness: 1.4 mm
  • Nominal Sheath Thickness: 1.9 mm
  • Approx Overall Diameter: 35 mm
  • Max DC Conductor Resistance at 20°C: 0.268 ohm/km
  • Weight: 2690 kg/km
  • Standard Length: 500 meters
  • Phase Core Color: Red, Yellow, Blue
  • Standard: IEC 60502-1
Contact Us

Stranded PVC Copper Cable 3 Core 70 mm, 0.6/1kV, 500 M | RESCAB

Unarmored stranded copper electric cable (CU/PVC/PVC), 0.6/1kV, 3 core + neutral line, 3×120 + 70mm2 size conductor, produced by Red Sea Cables (RESCAB) Company, PVC cables are a widely used and effective choice for power transmission in various applications.

  • Conductor: Stranded Copper
  • Insulation Material: PVC (Polyvinyl Chloride)
  • Outer Sheath: PVC
  • Voltage: 0.6/1kV
  • Number of Cores: 3.5 Core (3 Core + Neutral Line)
  • Conductor Size (Cross-Sectional Area): ( 3cx120 mm2 ) + 70mm2
  • Number of Phase Wires: 37
  • Number of Neutral Wires: 19
  • Nominal Insulation Thickness of Phase: 1.6 mm
  • Nominal Insulation Thickness of Neutral: 1.4 mm
  • Nominal Sheath Thickness: 2.3 mm
  • Approx Overall Diameter: 44 mm
  • Max DC Conductor Resistance at 20°C (Ph): 0.153 ohm/km
  • Max DC Conductor Resistance at 20°C (Ne): 0.268 ohm/km
  • Weight: 5080 kg/km
  • Standard Length : 500 meters
  • Phase Core Colors: (Red, Yellow, Blue, Black)
  • Standard: IEC 60502-1
Contact Us

Stranded PVC Copper Cable 3 Core 70 mm, 0.6/1kV, 500 M | RESCAB

Unarmored stranded copper electric cable (CU/PVC/PVC), 0.6/1kV, 3 core + neutral line, 3×120 + 70mm2 size conductor, produced by Red Sea Cables (RESCAB) Company, available in a variety of sizes and colors with the highest quality and best prices.

  • Conductor: Stranded Copper
  • Insulation Material: PVC (Polyvinyl Chloride)
  • Outer Sheath: PVC
  • Voltage: 0.6/1kV
  • Number of Cores: 3.5 Core (3 Core + Neutral Line)
  • Conductor Size (Cross-Sectional Area): ( 3cx120 mm2 ) + 70mm2
  • Number of Phase Wires: 37
  • Number of Neutral Wires: 19
  • Nominal Insulation Thickness of Phase: 1.6 mm
  • Nominal Insulation Thickness of Neutral: 1.4 mm
  • Nominal Sheath Thickness: 2.3 mm
  • Approx Overall Diameter: 44 mm
  • Max DC Conductor Resistance at 20°C (Ph): 0.153 ohm/km
  • Max DC Conductor Resistance at 20°C (Ne): 0.268 ohm/km
  • Weight: 5080 kg/km
  • Standard Length : 500 meters
  • Phase Core Colors: (Blue, Brown, Black, Grey)
  • Standard: BS 5467, 6346
Contact Us
Shopping Cart